Section 2.2: Changing How the NT9010 Works For Users
23
Enable both the Squawk on Away Arming/Disarming Only and the Arm/Dis-
arm Bell Squawk options to have the system squawk the bell only when the sys-
tem is away armed or disarmed.
If the Opening After Alarm Keypad Ringback option is turned on, the system
will beep the keypad 10 times rapidly if the system is disarmed after an alarm
occurred. If the Opening After Alarm Bell Squawk option is turned on, the sys-
tem will squawk the bell output 10 times rapidly if the system is disarmed after an
alarm occurred.
If the system is armed using the Stay function key, or by entering [✱][9][access
code], there will be no bell squawks during entry and exit delays, except for the
arm/disarm bell squawks.
Closing Confirmation, if enabled, will cause the keypad to beep 10 times rapidly
after the closing reporting code has been successfully transmitted to central station.
If you enable the WLS Key Does Not Use Access Codes option, the disarm but-
ton will work on wireless keys which have not been assigned access codes.
To prevent disarming by wireless keys which don’t have access codes, disable this
option. (See also 2.2.11 Programming Wireless Keys on page 31.)
Arm/Disarm Bell Squawk . . . . . . . . . . . . . . . . . . . . . . . . . Section [014], Option [1]
WLS Key Does Not Use Access Codes . . . . . . . . . . . . . . . Section [017], Option [1]
Bell Squawk on Away Arming . . . . . . . . . . . . . . . . . . . . . Section [017], Option [8]
Opening After Alarm Keypad Ringback . . . . . . . . . . . . . . Section [381], Option [1]
Opening After Alarm Bell Ringback . . . . . . . . . . . . . . . . . Section [381], Option [2]
Closing Confirmation. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [381], Option [4
2.2.6 Automatic
Arming
You can program the system to automatically arm at a specific time every day.
Three items must be enabled in order to activate the auto arming function:
1. The correct time of day must be programmed. For instructions on programming
the time and date, see the NT9010 User’s Guide (“Setting the Time and Date”).
2. Enter [✱][6][Master Code][2] to enable (three keypad beeps) or disable (one
long beep) the auto-arm feature.
3. Program the auto-arm time using the [✱][6][Master Code][3] command.
When the internal system clock matches the programmed auto arm time, the sys-
tem will check its status. If the system is armed, the NT9010 will do nothing until
the programmed auto-arm time for the next day, when it will check again.
If the system is disarmed at the auto-arm time, the NT9010 control unit will sound
the keypad buzzer for one minute. This is the auto arm pre-alert period.
If the Bell Squawk During Auto Arm option is enabled, the bell will squawk
while the system is auto-arming in order to notify anyone on the premises that the
system is being armed.
If a valid access code is entered during the auto arm pre-alert period, automatic
arming will be cancelled. If automatic arming is cancelled by a user, the system will
send the Auto Arm Reporting Code to the central station.
NOTE:The Maintenance code cannot be used to cancel automatic arming.