Chapter 2: Advanced Programming
24
If no code is entered during the auto-arm prealert, the system will auto-arm. If a
zone is violated when the system arms, the system will transmit a Partial Closing
Reporting Code (if programmed), to indicate the system was not secure. If the
zone is restored, the NT9010 will arm the zone and add it back into the system.
Program Time and Date. . . . . . . . . . . . . . . . . . . . . . . . . . . . [✱][6][Master Code][1]
Enable Auto Arming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [✱][6][Master Code][2]
Program Auto Arm Time . . . . . . . . . . . . . . . . . . . . . . . . . . . [✱][6][Master Code][3]
Partial Closing Reporting Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [343]
Auto Arm Cancellation Reporting Code. . . . . . . . . . . . . . . . . . . . . . . Section [348]
Bell Squawk During Auto Arm . . . . . . . . . . . . . . . . . . . . . Section [014], Option [2]
2.2.7 Entry and Exit
Delay Options
Upon arming, the system will begin the exit delay. If Audible Exit Delay is enabled
the keypad will beep every second until the exit delay expires. The keypad will beep
rapidly for the last 10 seconds of exit delay to warn the user the system is about to
arm.
Users can restart the exit delay one time while it is counting down by pressing the
Away key. The system will not log the user who re-started the exit delay, unless the
Quick Arming Disabled/Function Keys Require Code option is turned on (sec-
tion [015], option [4]).
NOTE: If the system has been Stay armed, or armed with no entry delay
([✱][9]), pressing the Away key will not start an exit delay.
For some applications Bell Squawk on Exit Delay may be enabled. The system
will squawk the alarm output once every second when the exit delay is initiated
and 3 times a second for the last 10 seconds until the exit delay expires.
Upon entry, if a Delay type zone is violated, the system will begin entry delay. The
keypad will emit a steady tone. The keypad will pulse the keypad sounder during
the last 10 seconds to warn the user the system is about to go into alarm. If there
was an alarm during the armed period, the keypad sounder will pulse for the entire
entry delay to warn the user of the previous alarm.
For some applications Bell Squawk on Entry Delay may be enabled. The system
will squawk the alarm output once every second until the entry delay expires or the
system is disarmed.
NOTE:Since two Delay zones are programmable, and therefore two differ-
ent Entry Delays, when the system is armed it will use the Entry Delay for
the first Delay zone violated.
If Exit Delay Termination is enabled the system will monitor the Delay zones dur-
ing exit delay. If a Delay type zone is violated then secured during the exit delay, the
exit delay will be terminated and the system will be armed immediately.
To prevent false alarms, use the built-in feature Audible Exit Fault. If a delay type
zone is violated within 10 seconds after the exit delay has expired, the system will
sound the entry delay warning through the keypad and siren alerting the customer
that an improper exit was made. If the system is disarmed within the entry delay no
signal is sent. If not, the system will continue to sound the alarm and send a signal
to central station. This feature can be disabled in Section [013] Option [6].