Chapter 2: Advanced Programming
30
[04] - Away Arm
Arms the system in Away mode. All Stay/Away type zones will be active at the end
of the exit delay. Delay type zones will provide entry and exit delay. The Quick Arm
feature must be enabled for this key to function (Section [015], option [4]). If Quick
Arming is not enabled, the user must enter a valid access code after pressing the
function key in order to arm the system in the Away mode.
[05] - []+[9] No-Entry Delay Arm
After this function key is pressed the user must enter a valid access code. The sys-
tem will arm and remove entry delay from the system when the exit delay expires
(see [*] [9] Arming Without Entry Delay on page 28).
[06] - []+[4] Door Chime On/Off
Pressing the key will toggle the Door Chime feature ON or OFF. One solid beep
means the feature has been disabled, three short beeps means it has been enabled.
[07] - []+[6]...[4] System Test
This function key provides the user with a simple method for testing the system
(see [*] [6] User Functions on page 27).
[08] - []+[1] Bypass Mode
This function key provides the user with a simple method for entering the Bypass
Mode. If an access code is required it must be entered before bypassing can be per-
formed (see [*] [1] Zone Bypassing on page 25).
[09] - []+[2] Trouble Display
This function key provides the user with a simple method for entering the Trouble
Display Mode (see [*] [2] Trouble Announcements on page 26).
[10] - []+[3] Alarm Memory
This function key provides the user with a simple method for entering the Alarm
Memory Display Mode (see [*] [3] Alarm Memory on page 27).
[11] - []+[5] Programming Access Codes
This function key provides the user with a simple method for programming access
codes. After this key is pressed a valid System Master or Supervisor Code will have
to be entered before the system will allow programming to be performed (see [*]
[5] Programming Access Codes on page 27).
[12] - []+[6] User Functions
This function key provides the user with a simple method for programming User
Functions. After this key is pressed a valid System Master or Supervisor code must
be entered before the system will allow User Functions to be performed (see [*]
[5] Programming Access Codes on page 27).
[13] - [15] For Future Use
[16] - []+[0] Quick Exit
Pressing this key will cause the system to activate the Quick Exit feature (see section
[*] [0] Quick Exit on page 29).