Envoy NT9010A Przewodnik Instalacji Strona 49

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 48
Section 2.3: Changing Other NT9010 Functions
45
Cross Zone Police Code Reporting
The system will transmit the Cross Zone Police Code reporting code, if programmed,
when two different zones are violated within the same armed-to-armed period.
Cross Zone Police Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [328]
Delinquency Reporting
The Delinquency feature is used to monitor system activity. When the Delinquency
Transmission Delay timer expires, the system will transmit the Delinquency
reporting code.
If the system is programmed to monitor Activity Delinquency, the timer will be
programmed in hours. The timer will start under the following conditions:
When the system is armed in the Stay mode
When the system is disarmed
When a zone is violated and restored while the system is disarmed/Stay armed
(Interior, Interior Delay, Interior Stay/Away, or Delay Stay/Away zones only).
The activity delinquency timer will be ignored when the system is armed in the Away
mode. Zones that are bypassed in the [][1] Bypass menu will not reset the timer.
If the system is programmed to monitor Closing Delinquency, the timer will be
programmed in days. The timer will restart every time the system is disarmed.
Activity/Closing Delinquency . . . . . . . . . . . . . . . . . . . . . . Section [380], Option [8]
Delinquency Transmission Delay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [370]
Zone Restorals
If the Restoral on Bell Time-out option is selected, the system will send the Zone
Restoral Reporting Code for the zone if the bell cut-off time has expired and the
zone is secured. If the zone is not secured when the bell cut-off time expires, the
system will send the restoral immediately once the zone is secured, or when the
system is disarmed. If the Restoral on Bell Time-out option is not selected, the
system will immediately send the Zone Restoral Reporting Code when the zone is
secured, regardless of whether or not the alarm output is active.
NOTE:24 Hour type zones will report the restoral immediately when the
zone is secured.
Restoral on Bell Time-out. . . . . . . . . . . . . . . . . . . . . . . . . Section [380], Option [2]
AC Failure Communication Delay Time . . . . . . . . . . . . . . . . . . . . . . . Section [370]