Chapter 2: Advanced Programming
32
3. Enter the 2-digit code from the list below for the function you want the button
to have:
4. Repeat steps 1 to 3 until all buttons are programmed.
Wireless Key Function
Button Programming . . . . . . . . . . . . . . . . . . . . . . .Sections [804]-[61] to [804]-[64]
WLS Key Does Not Use Access Codes . . . . . . . . . . . . . . . Section [017], Option [1]
2.2.12 Fire, Auxiliary
or Medical,
and Panic
Keys
Three emergency keys are available on the NT9010. Each pair of keys must be
pressed and held for 2 seconds before they will activate. This 2 second delay is
designed to help prevent accidental activation. If the Fire Keys option is enabled,
when the Fire keys are pressed and held for 2 seconds, the system will activate the
alarm output. It pulses one second on, one second off only if option 8 of Section
[013] is disabled (Standard Fire option). If Fire Bell Continuous is selected the
alarm output will sound until a code is entered; otherwise it will sound until a code
is entered or the alarm output times out. Communication of the signal to central
station is immediate.
If the Auxiliary ( ) or Medical ( )* keys are pressed and held for 2 seconds, the
unit beeps three times to verify activation. The system will beep the keypad ten
times rapidly to verify communication to the central station.
If the Panic keys are pressed and held for 2 seconds, the system will immediately
communicate the signal to central station. If Panic Keys Audible is enabled, the
system will beep the keypad three times upon activation and activate the alarm
output until a code is entered or the alarm output times out. Otherwise the alarm
will be completely silent.
NOTE:The Fire, Auxiliary or Medical, Panic keys will operate even if Keypad
Lockout is active (see 2.2.13 Keypad Options on page 33).
Fire Keys Enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [015], Option [1]
Panic Keys Audible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [015], Option [2]
Fire Bell Continuous. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [014], Option [8]
*If the unit is to be used in home health care applications, the unit must have Med-
ical ( ) keys and not Auxiliary ( ) keys.
Entry Description
Can Be Used on
Wireless Key
00 Null Key (Key not used) Yes
03 Stay Arm Yes
04 Away Arm Yes
06 Door Chime On/Off Yes
07 System Test Yes
16 Quick Exit Yes
17 Activate Stay/Away Zones Yes
27 Disarm (Off) Yes
28 FIre Alarm Yes
29 Auxiliary or Medical Alarm Yes
30 Panic Alarm Yes
Komentarze do niniejszej Instrukcji